Frequency of testing electrical safety testing.
Domestic electrical inspection frequency.
Periodic test and inspection.
Tests are also carried out on wiring and fixed electrical equipment to check that they are safe.
Reveal if any of your electrical circuits or equipment are overloaded.
Most of the information produced by the hse is available for immediate download.
Highlight any lack of earthing or bonding.
Identify potential electrical shock risks and fire hazards.
Domestic accmomdation rented.
Identify any defective electrical work.
Periodic test and inspection suggested frequency general installation.
Residential accommodation hmo halls of residence etc.
Electrical inspection and testing hse and other organisations have produced guidance on electrical safety that is suitable for a wide range of industries and technical competencies.
For instance the maximum period between inspections and testing in an industrial environment is 3 years whereas for shops it s every 5 years.
Frequency between inspections and testing as necessary see notes below domestic general.
Change of occupancy 5.
Combined inspection test.
The 18th iet edition wiring regulations bs 7671 2018 sets out a table detailing the guidance on the frequency of formal inspections of electrical installations as well as routine checks.
Find any potential electric shock risks and fire hazards.
A periodic inspection will.
The frequency of periodic inspection and testing must be determined taking into account various factors.
Change of occupancy 10 years.
A recommendation for the interval to the first periodic inspection should be provided by the electrical installation designer and recorded on the electrical installation certificate regulation 134 2 2 in making the recommendation the designer should together with the factors listed earlier also take into account the frequency and.
The table below provides guidance on the frequency of formal inspections of electrical installations as well as routine checks.
Discover if electrical circuits or equipment are overloaded.
Change of occupancy 10 yrs.
Find any defective electrical work.
Change of occupancy 5 years.
Table extracted from bs7671 iet wiring regulations 18th edition.
Bs 7671 states the maximum intervals between inspections and an electrical inspector may specify a lower frequency based on factors such as condition and age.
A periodic inspection checks the condition of an existing electrical installation against bs 7671 the uk standard for the safety of electrical installations.