Connection of first valve 5 x1 y4.
Daikin fan coil units wiring diagram.
Coil cross fin coil rows stages fpi 3 26 13 3 26 13.
Wire to enable the use of the second valve supplied with valve kit 6 x2 y2.
Daikin fan coil units deliver quiet reliable controllable comfort of air conditioning without all the noise of other central systems.
Always contact your daikin dealer for advice and information.
All other uses are considered improper.
Ducted fan coil units english installations und bedienungsanleitung kanal ventilator konvektoren.
Indoor fan motor units power supply ifm input w model hz volts voltage range mca mop kw fla cooling heating fxmq72mvju.
1 communication to fan coil pcb 2 power supply wire to fan coil unit 3 fuses 5 a 250 v 4 yc y1.
Fan coils come in three basic configurations.
In warmer climates or when a building is well insulated fan coil units with a chiller 2 pipe system can handle both cooling and heating.
2 3 globally leading daikin fan coil technology daikin china contents 04 unit characteristics 08 13 14 15 electric wiring diagram temperature controller and valves.
Wiring diagrams edus39 900a f11 a 6 fxmq m 5.
It is required to use a minimum of 18 gauge wire maximum operating length of wire is 125 ft.
Connection of second valve do not bundle low and high voltage wires together.
All electrical wiring must not touch the water piping or any moving parts of the fan motors.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
Operating limits are shown here below.
Wiring diagram on the cover of the electrical box.
Horizontal in or along the ceiling vertical running the height of the wall and unit heaters low along the wall.
Fan coil units in combination with chillers and or boilers can be used to provide a broad range of solutions that can be tailored to local conditions such as climate primary fuel market or building insulation.
Coil cross fin coil rows stages fpi 2 14 17 2 14 17 2 14 17 face area ft m 1 73 1 73 1 73 fan model qcl9661m qcl9661m qcl9661m type cross flow fan cross flow fan cross flow fan motor output w 40 40 40 air flow rate h l cfm m3 min 260 160 79 49 280 175 85 53 290 180 88 55 drive direct drive direct drive direct drive.
Wiring diagrams fxmq72 96mvju 3d065414c.
Bundle all wires with the included clamps in order to.
Only four wires required to connect each component.
The unit must be grounded to prevent possible hazard due to insulation failure.
Fan coils can either be exposed with a painted metal cabinet occupying the conditioned space or recessed with a wall plate or ductwork connecting it to the conditioned space.
Communicating outdoor unit dx17vss compatible communicating indoor unit white green red black eev coil daikin one smart thermostat 6 14 2019 notes.