Field testing is generally performed to satisfy project specifications.
Curtain wall water testing equipment.
The astm e 1105 standard test method for field determination of water penetration of installed exterior windows skylights doors and curtain walls is used for water penetration testing and the astm e 783 standard test method for field measurement of air leakage through installed exterior windows and doors is used for air infiltration testing.
Astm e1105 testing is used to determine the resistance of windows curtain walls skylights and doors to water penetration.
Below are the types of tests and links for additional details to the various performance specifications.
You can view a video of astm e1105 here.
Common problems with these systems include water leakage air infiltration and failed insulated glass units.
Storefront and curtain wall systems are similar in appearance but differ in the way water drainage mechanisms are used.
Laboratory testing structural astm e330.
American field testing along with american test lab an ias accredited lab also offers curtain wall testing at atl s facility in brevard nc air water structural and dynamic testing on specimens up to 29 x 40.
Our testing equipment is highly portable so we can perform this service anywhere.
Aama 1605 1 1606 x en 12179 cwct section 11 12 resistance to wind loading x.
Storefront curtain wall testing.
Laboratory testing thermal aama 1503 1506.
Details related to their design and installations vary among manufacturers.
Aftnc offers the highest level of testing and evaluations with state of the art equipment and qualified technicians that can be completed in field conditions.
In addition to our 40 years of experience testing to aama astm and fbc tas and en standards we can ensure your curtain wall meets individual project specifications.
Cwct section 17 structural movement x na en 13830 curtain wall testing x.
Astm e 331 standard test method for water penetration of exterior windows skylights doors and curtain walls by uniform static air pressure difference.
If you are looking for a test that measures water resistance in extreme weather conditions refer to the aama 502 aama 503 or the astm e 1105.
Field testing of a storefront system to american architectural manufacturers association aama 503 voluntary specification for field testing of newly installed storefronts curtain walls and sloped glazing systems an exterior pressure chamber establishes the pressure differential and a calibrated spray rack is located inside the chamber.
The aama 501 2 quality assurance and diagnostic water leakage field check of installed storefronts curtain walls and sloped glazing systems is designed to aid in the water tight testing of large glass areas meant to be permanently closed such as store fronts curtain walls and sloped glazing systems.